Solar Calculator Canada

Solar Power Calculator for Harrington Harbour, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Harrington Harbour
  • GPS Coordinates: 50.5, -59.4797222
  • Elevation: 0 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Harrington Harbour: 35o
  • Average yearly irradiance: 1158.88 kWh/m2
  • Average yearly power output: 99221.6 kWh
Sun Path Harrington Harbour

Average yearly irradiance delivered by the Sun in Harrington Harbour is 1158.88/kWh/m2 at the optimal panel slope of 35o. After taking all losses into account, you can expect about 99221.6 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 35o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 0.91 28.34
February 1.58 44.19
March 2.54 78.67
April 3.52 105.52
May 4.89 151.72
June 5.16 154.76
July 5.15 159.78
August 4.74 146.8
September 3.84 115.06
October 2.97 91.96
November 1.74 52.11
December 0.97 29.97
Total yearly 1158.88

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 75.65 2345.19
February 132 3696.06
March 214.66 6654.44
April 300.03 9000.84
May 418.76 12981.7
June 441.33 13240
July 441.79 13695.5
August 406.74 12608.9
September 331 9929.94
October 257.8 7991.76
November 151.05 4531.63
December 82.12 2545.77
Total yearly 99221.6

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Harrington Harbour solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 60.03 1861.03
February 110.38 3090.52
March 195.5 6060.45
April 295.94 8878.13
May 428.94 13297
June 461.73 13851.9
July 457.03 14168
August 402.84 12487.9
September 302.98 9089.52
October 213.88 6630.22
November 113.76 3412.7
December 61.21 1897.66
Total yearly 94725.1

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 64.63 2003.57
February 116.96 3274.95
March 201.99 6261.81
April 299.12 8973.64
May 429.65 13319
June 460.1 13803
July 456.81 14161.1
August 406.92 12614.5
September 312.66 9379.95
October 227.1 7040.15
November 124.49 3734.71
December 67.2 2083.18
Total yearly 96649.5

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 68.73 2130.65
February 122.71 3435.91
March 207.32 6426.97
April 300.89 9026.74
May 428.18 13273.5
June 456.33 13689.9
July 454.12 14077.9
August 408.97 12678.2
September 320.53 9615.93
October 238.74 7400.84
November 134.2 4026
December 72.63 2251.59
Total yearly 98034.1

Harrington Harbour Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 72.33 2242.09
February 127.62 3573.42
March 211.48 6555.84
April 301.25 9037.36
May 424.72 13166.4
June 450.24 13507.3
July 449.33 13929.2
August 409 12679
September 326.56 9796.84
October 248.77 7711.73
November 142.86 4285.92
December 77.5 2402.43
Total yearly 98887.5

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.09% angle of incidence loss and -1.84% temperature and irradiance loss. This totals to about -14.38%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: